Timestep Calculation

Attached is a simple Excel sheet that can be used to quickly evaluate the timestep calculated by LS-DYNA for solids, beams and shells. It must be noted that for solid elements, Q is based on the C1 (default = 0.06) only. timestep.xls Update For solid elements using MAT_SPOTWELD, LS-DYNA uses a slightly different method of…

January 10, 2008 | by

CONTACT_AUTO_MOVE to eliminate initial contact clearances

In many situations, initial clearances between two contact surfaces can cause convergence issues in IMPLICIT analyses while wasting simulation time in EXPLICIT analyses. To remove the initial contact clearance, LS-DYNA offers a capability using *CONTACT_AUTO_MOVE that helps to improve convergence in IMPLICIT analyses since contact is detected immediately. Contact AUTO_MOVE associates itself with another contact…

January 10, 2008 | by