SPC Constraints in Dynamic Relaxation to Improve Convergence
Stabilizing structures in Dynamic Relaxation Phase to improve convergence.
Stabilizing structures in Dynamic Relaxation Phase to improve convergence.
In traditional explicit analysis, there is no convergence criteria that is checked for each time step. However, in Implicit calculations, incremental displacements are evaluated such that a displacement norm and the energy norm are within a pre-defined tolerance before convergence is assumed to be obtained. This is the so-called iterative scheme in Implicit Non-Linear Analyses…